![brivis buffalo service manual brivis buffalo service manual](https://i.ebayimg.com/images/g/YzwAAOSwD3JbdPs9/s-l640.png)
![brivis buffalo service manual brivis buffalo service manual](http://entrancementvine.weebly.com/uploads/1/2/3/7/123753700/608672678.jpg)
![brivis buffalo service manual brivis buffalo service manual](https://i.ytimg.com/vi/6FUUjjSu3a8/maxresdefault.jpg)
#BRIVIS BUFFALO SERVICE MANUAL ZIP#
Input (max), W 775 L/s (1640 CFM) Output (max), W/XA 890 L/s (1850 CFM) Electrical: 240 Volts Burner Quantity: 7 Motor: Betts Gas Rate (MJ/h): std X.A NG LPG 61S (old) 61S (old) Maximum: S (new) 61S (new) Minimum: Watt: Amps: 4 5 Burner Pressure (pa): R.P.M Maximum: H/P: 3/4 1 Minimum: Fan Wheel: Injector Orifice: 270 mm X 270 mm 270 mm X 270 mm NG LPG (10" X 10") (10" X 10") Main Burner Zip Burner Pilot Burner Capacitor: Plessey Plessey P uf (New Motor) 20 uf (old Motor) Speed Controller VA: 1000 Gas Valve: Model VR800 (Stat to be on.2) Incorporates: Regulator, Main gas solenoid-24 volt operator, Three position Gas Cock, Pilot Electromagnet and redundant valve.
#BRIVIS BUFFALO SERVICE MANUAL MANUAL#
1 Brivis Service Manual Heater - Pre Electronic (Fan & Limit ) Models Buffalo 120 Buffalo 85 Wombat 120 Wombat 92 Upflow 120 Upflow 92 Downflow 92 Service Manual 7 Heater Pre Electronic Fan & Limit Control Approved Issue 2 Printed 13-Feb-14 11:53:12 AM 1Ģ Index Page Technical Information Buffalo Wombat Upflow Downflow.10 Technical Drawings External 85 MJ.11 External 120 MJ.12 Interanl 92 MJ.13 Internal 120 MJ.14 Electronic Thermostat with Add-On Cooling.15 Electronic Thermostat Remote Fan Switch VA Speed Control on 120 MJ Heaters.17 Standard Valve VR / 92 MJ Models MJ Models.20 Operation Unit Operation.21 Lightening Procedure EPR Operation EPR Retrofit Instructions.26 Varistor Onwards.27 Closed Circuit Resistor Onwards.27 Transformer Fan Speed Controller.27 Flame Roll-out Detection Switch.27 Summer Fan Operation.27 Thermocouple and Electromagnet Gas Valve Operation Burner Operation.35 Main Burner.36 Zip Burner.36 Service Procedure Instructions to Adjust the Fan Speed.37 Check List for Unit Not Operating.38 If Pilot will not Light.39 If Pilot Lights, But will Not Stay Alight.40 If the Pilot Flame will Not Light.40 If No Gas at Pilot Burner.40 Replacing and Adjusting the Pilot Injector.41 Main Burner will Not Light when Gas Control Knob is Turned to the ON Position.42 Service Manual 7 Heater Pre Electronic Fan & Limit Control Approved Issue 2 Printed 13-Feb-14 11:53:12 AM 2ģ Index Page Service Procedure (cont.) Delayed Ignition and Poor Ignition Check List for Fan will Not Operate.45 Check List for Fan will Not Turn Off.45 Heater Going Off on Overheat (Fan Limit Control).46 Flame Roll-Out (Buffalo Models Only).47 Heater Turns Off on Anti-Flame Roll-Out Device.48 Gas Valve Blockages.49 Gas Valve Regulator Replacement.50 Gas Valve Main Operator.51 Gas Valve Redundant Solenoid.52 Gas Valve Electromagnet Maintenance Burner.55 Pilot.55 Fan.55 Dismantling Procedures Front Panel Removal.56 Burner Removal.56 Manifold and Control Assembly Removal.56 Flue Terminal Removal.56 Heat Exchanger Removal.57 Convection Fan Removal.57 Conversion.58 Service Manual 7 Heater Pre Electronic Fan & Limit Control Approved Issue 2 Printed 13-Feb-14 11:53:12 AM 3Ĥ Technical Information Buffalo 120 AGA Approval No.: Mass kg: 114 Dimensions (mm): Width Height Depth Air Quantity: MJ BTU 125 pa Ext.